THERMOSTAT INSPECTION


BHE011215171W02

1. Inspect the thermostat for the following.

Warning
• During inspection, the thermostat and water are extremely hot and they can cause burns. Do not touch the thermostat and water.
• The valve shall not open under normal temperature.
• Opening temperature and valve lift
– If there is any malfunction, replace the thermostat.

Item

Specification

Initial-opening temperature
(°C {°F})
80-84 {176-183}
Full-open temperature
(°C {°F})
95 {203}
Full-open lift
(mm {in})
8.5 {0.33} or more