SECONDARY AIR INJECTION (AIR) CONTROL VALVE INSPECTION
BHE011613988W02
1. Remove the secondary air injection control valve. (See SECONDARY AIR INJECTION (AIR) CONTROL VALVE REMOVAL/INSTALLATION.)
2. Verify that there is no air flow between A and B of the AIR control valve port.
-
• If there is air flow, replace the AIR control valve. (See SECONDARY AIR INJECTION (AIR) CONTROL VALVE REMOVAL/INSTALLATION.)
3. Install the vacuum pump to the AIR control valve.
4. Pressurize the actuator valve of the AIR control with a negative pressure of approx. 60 kPa {0.61 kgf/cm2, 8.7 psi}.
-
Caution
-
• Since the valve actuator of the AIR control could be damaged, do not pressurize positive pressure or negative pressure more than 100 kPa {1.02 kgf/cm2, 14.5 psi}.
5. Blow air through port A, then verify that there is air flow.
-
• If there is no air flow, replace the AIR control valve. (See SECONDARY AIR INJECTION (AIR) CONTROL VALVE REMOVAL/INSTALLATION.)
6. Blow air from through port B, then verify that there is no air flow.
-
• If there is air flow, replace the AIR control valve. (See SECONDARY AIR INJECTION (AIR) CONTROL VALVE REMOVAL/INSTALLATION.)