1. Remove the battery and then place it in a pan of water.
2. Connect a battery charger to the battery and adjus the charging current as follows.
Standard specification
Battery type
(5-h rate)
|
Recharge current (A)
|
Quick charge
(A/30 min)
|
---|---|---|
50D20L (40)
|
4.0-5.0
|
25
|
75D23L (52)
75D26L (52)
|
5.0-6.0
|
35
|
3. After the battery is recharged, verify that the voltage is within the specification and remains at the same value for 1 h or more after the recharging was stopped.