NEUTRAL SWITCH INSPECTION


BHE014017640W01

Note
• Before performing the following inspection, make sure to follow the troubleshooting flowchart. (See Troubleshooting Procedure.)

Continuity Inspection

1. Remove the neutral switch.

2. Verify that the continuity between neutral switch terminals 1A and 2A is as indicated in the table.

• If there is no malfunction, perform the "Circuit Open/Short Inspection".
• If there is any malfunction, replace the neutral switch.

Measurement condition

Continuity

6MT

5MT

Push the rod.
No continuity
Continuity detected
Except above
Continuity detected
No continuity

Circuit Open/Short Inspection

1. Disconnect the PCM connector.

2. Disconnect the neutral switch connectors.

3. Inspect the following wiring harnesses for open or short circuit. (Continuity inspection)

Open circuit

• If there is no continuity in the following wiring harnesses, there is an open circuit. Repair or replace the wiring harness.
– Neutral switch terminal 2A and PCM terminal 2O
– Neutral switch terminal 1A and body ground

Short circuit

• If there is continuity in the following wiring harnesses, there is a short circuit. Repair or replace the wiring harness.
– Neutral switch terminal 2A and body ground
– Neutral switch terminal 2A and power supply