DTC INSPECTION (IMMOBILIZER SYSTEM)
BHE090201077W02
Security Light
1. Turn the ignition switch to the ON position.
2. Verify the security light state.
-
• If there is any malfunction:
-
– After any malfunction is detected, the security light will function as follows for approx. 1 min.
-
• DTC 16 and lower: Flashes
-
• DTC 21 and higher: Illuminated
-
• If there is no malfunction:
-
– The security light illuminates for approx. 3 s and goes out.
3. When any malfunction has been detected, read DTCs via flashing patterns displayed after the security light flashes or is illuminated for approx. 1 min.
-
• Perform troubleshooting according to the corresponding DTC inspection.
-
Note
-
• A verified DTC is flashed 10 times repeatedly by the security light.
-
• If multiple DTCs are verified, the security light displays only the smallest DTC.
WDS OR EQUIVALENT
1. Connect the WDS or equivalent to the DLC-2.
2. Verify if any DTCs are displayed.
-
• If any DTCs are displayed, carry out troubleshooting according to the corresponding DTC inspection.
3. Disconnect the WDS or equivalent.