SECONDARY SHUTTER VALVE (SSV) SOLENOID VALVE INSPECTION
BHE011301005W12
1. Disconnect the negative battery cable.
2. Remove the SSV solenoid valve. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION.)
3. Inspect for airflow using the steps in the table below.
-
• If it is normal, inspect related wiring harnesses.
-
• If there is any malfunction, replace the SSV solenoid valve.
Circuit Open/Short Inspection
1. Disconnect the PCM connector. (See PCM REMOVAL/INSTALLATION.)
2. Inspect the following wiring harness for open or short (continuity check).
Open circuit
-
• If there is no continuity, the circuit is open. Repair or replace the harness.
-
– SSV solenoid valve terminal B (harness-side) and PCM terminal 1L
-
– SSV solenoid valve terminal A (harness-side) and main relay terminal C (harness-side)
Short circuit
-
• If there is continuity, the circuit is shorted. Repair or replace the harness.
-
– SSV solenoid valve terminal B (harness-side) and body GND
-
– SSV solenoid valve terminal A (harness-side) and power supply